Philips Healthcare · Model IntelliVue MP5SC
Multipurpose monitoring Innovative and informative, the MP5SC offers SpO2, NBP, SureTemp, and Microstream CO2. The monitor can be used in spot-check as well as continuous monitoring mode. In continuous mode, the IntelliVue MP5SC can be used for reliable longer-term bedside monitoring. Its optional EWS Escalation package allows the MP5SC to convert to a full ECG monitor via a patient-worn device when enhanced monitoring is required, such as during a code event. See more, and see it earlier Introducing IntelliVue Guardian Early Scoring, the IntelliVue MP5SC is fully configurable with EWS, providing caregivers on the general floor with direct access to an automated scoring system based on their own hospital’s policy and guidelines. Whatever the level of patient acuity and frequency of vital sign collection, IntelliVue Guardian EWS can help caregivers identify patient deterioration earlier with faster and easier Early Warning Score calculations. Easy to use The MP5SC supports efficient workflow, helping caregivers in a variety of settings to simply measure, evaluate, and document their patient’s vital signs and EWS scores. Aids rapid response IntelliVue Guardian EWS helps enable faster activation and intervention of the institution's rapid response or escalation system when appropriate. Once the response team has arrived, the monitor can provide full ECG monitoring. IntelliVue Guardian solutions are designed to help enhance patient care throughout your facility.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature, CO2 or CO intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a parameter-module / input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: The host does not display a plugged-in module or a built-in parameter.
Root cause: Docking / connector fault or an internal board fault.
Symptoms: Blank, dim or distorted display; unresponsive touchscreen.
Root cause: Display, backlight, or controller fault.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack or a power-supply fault.
Symptoms: Monitor not shown at the central station, admit fails, intermittent drop.
Root cause: Wired / Wi-Fi network configuration or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Parameter module / input board | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Display / touchscreen assembly | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.