Philips Healthcare · Model IntelliVue MP5SC
Multipurpose monitoring Innovative and informative, the MP5SC offers SpO2, NBP, SureTemp, and Microstream CO2. The monitor can be used in spot-check as well as continuous monitoring mode. In continuous mode, the IntelliVue MP5SC can be used for reliable longer-term bedside monitoring. Its optional EWS Escalation package allows the MP5SC to convert to a full ECG monitor via a patient-worn device when enhanced monitoring is required, such as during a code event. See more, and see it earlier Introducing IntelliVue Guardian Early Scoring, the IntelliVue MP5SC is fully configurable with EWS, providing caregivers on the general floor with direct access to an automated scoring system based on their own hospital’s policy and guidelines. Whatever the level of patient acuity and frequency of vital sign collection, IntelliVue Guardian EWS can help caregivers identify patient deterioration earlier with faster and easier Early Warning Score calculations. Easy to use The MP5SC supports efficient workflow, helping caregivers in a variety of settings to simply measure, evaluate, and document their patient’s vital signs and EWS scores. Aids rapid response IntelliVue Guardian EWS helps enable faster activation and intervention of the institution's rapid response or escalation system when appropriate. Once the response team has arrived, the monitor can provide full ECG monitoring. IntelliVue Guardian solutions are designed to help enhance patient care throughout your facility.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →