Philips Healthcare · Model HeartStart FRx
Simple to use Calm, clear voice instructions are precisely timed to the responder’s actions, guiding the responder every step of the way. Simplify the rescue of a child with the Infant/Child key Unique in the industry, the Infant/child key turns the HeartStart FRx into a pediatric defibrillator, tailoring the voice instructions and therapy to the needs of a child. Designed for real-world use, the HeartStart FRx was built to surpass rigorous testing requirements: jetting water, crushing loads up to 500 pounds and a one-meter drop onto concrete Ready when needed HeartStart FRx automatically conducts self-tests every single day, not just weekly. performs over 85 different tests in all. Even the pads are tested for readiness. Rapidly delivering a shock after chest compressions is critical. The HeartStart FRx’s Quick Shock feature delivers therapy in just 8 seconds (typical) after chest compressions.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Charge fails or sluggish, low-energy delivery.
Root cause: Capacitor aging / leakage.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Expiration-dated consumable.
Critical, keep charged spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
| Charge relay / contactor | Periodic replacement | $$$ | Difficult |
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical, keep charged spares. | Periodic replacement | $$$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →