Partec · Model CyFlow Space
Employing 3 solid state laser light sources. The light source system of the CyFlow® space in its fully equipped configuration comes with a 20mW@488nm blue solid state laser (200mW optional), a 40mW@635nm red diode laser (40mW optional), and a 75mW@405nm violet diode laser or 16mW@375nm UV laser diode, all with direct light coupling for maximum sensitivity. Due to the built-in colour CCD camera, the stability of the sample flow can be visually controlled by a video flow monitor. Featuring unique fluorescence sensitivity. By avoiding fiber coupling, the performance of the CyFlow® instruments is characterized by a superior fluorescence sensitivity of <100 MESF (FITC) and <50 MESF (PE) - see figure belowon the left - and by going to nano-resolution in the scatter channel - see figure below on the right. Any application focussing on small particle detection and analysis, requiring highest fluorescence intensity, fluorescence sensitivity as well as scatter resolution benefits from the unique performancecharateristics of the CyFlow®space. The unique Partec quartz flow cuvetteis the heart of the CyFlow®space, ensuring that particles and cells cross the excitation light with the best possible precision. The design of the flow cuvette incorporates more than 40 years of experience in handling fluids with sub-micrometer and nanoliter precision. Thanks to the optical and mechanical precision of the flow cuvette, superior results are guaranteed for all parameters, e.g. coefficients of variation (CVs) of about 2 % on all fluorescence channels. The sample is transported with the help of a computer controlled digital syringe pump, part of a virtually cross-contamination-free fluid system. Partec Particle and Cell Sorter PPCSas built-in module for safe closed piezo sorting offering highest purity and sorting stability. The Partec particle and cell sorter PPCS is the result of more than 40 years of experience in the field of flow cytometry for research and routine applications in cell and particle characterization. The PPCS can be used as an add-on to the Partec CyFlow®space or the PAS and serves as an optimized module for simplified and precise cell sorting. In order to overcome the problems of droplet sorters (biohazard, contamination) Partec has developed this closed sorting system. The PPCS sorting device can be sterilized safely. Any environmental contamination is completely avoided under normal operation conditions. In addition, the sorting action takes place smoothly. Fragile cells or large particles are sorted without any distortion and other forces acting on the cells during deflection. Long sorting runs (for several hundred milliliters of sample volume) are possible.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Bead CVs out of spec, scatter or fluorescence signal low or noisy, compensation drift.
Root cause: Flow-cell contamination or an air bubble, laser degradation / misalignment, or an optics / PMT fault.
Symptoms: Unstable event rate, boost / prime failures, sheath or waste alarm, clogs.
Root cause: Sheath / waste tank issue, a peristaltic / vacuum fault, or a partially blocked sample line / flow cell.
Symptoms: No or low event rate, probe-position error, carryover.
Root cause: Clogged or bent sample probe, or a clot.
Symptoms: A laser-line-specific parameter fails, laser-error message.
Root cause: Laser at end of life or a power-supply / interlock fault.
Symptoms: Acquisition hangs, data will not export, instrument not recognised.
Root cause: Workstation PC or the acquisition software / link.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flow cell | Periodic replacement | $$$ | Difficult |
| Sample probe / SIP | Periodic replacement | $$ | Moderate |
| Peristaltic pump tubing | Frequent wear item | $ | Moderate |
| Sheath / waste filters | Frequent wear item | $ | Easy |
| Laser | Periodic replacement | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.