Software Partec FloMax® FCM Data Acquisition and Analysis Software Windows™ based Partec FloMax® software is including multiple online gating, logical gates, and colour gating. N-colour online and offline software compensation is an other unique feature of FloMax® software. Data may be acquired with compensation or as uncompensated raw data. Either way compensation can be done, undone or changed after analysis on stored data. For data elaboration quadrant analysis, cell cycle analysis, peak analysis and other sophisticating features are available. An optional report function allows the generation and the individual design of analysis report sheets as Word or Excel documents. FloMax® data files are stored in FCS standard and therefore fully compatible to other commercial FCM data elaboration software solutions. FloMax® software already is pre-installed on the Windows™ PC delivered as part of the CyFlow® ML system. The Partec CyFlow® ML is supplied with additional 3 offline laboratory licenses free of charge, offering a cost-effective solutions also for working groups with need for offline FCM analysis software installations. Options Flexible and Modular Options and Upgrades for Partec CyFlow® ML Up to five light sources (e. g. laser light sources, modern high power LEDs and UV mercury arc lamp) and up to sixteen optical detectors yield an unlimited matrix of configurations for the Partec CyFlow® ML. Please contact the Partec Science and Application team for your specific requirements.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.