High-resolution 8.4” TFT color LCD display for showing ECG, pulse, energy charge, 12-lead ECG, CO2/SpO2/NIBP/IBP/Temp Up to 6 traces can be shown simultaneously Provides intuitive and user-friendly AED function and external pacing Paddles that include external and internal paddles and disposable pads can be easily changed with one connector 12-lead ECG data can be shared with mobile devices via Bluetooth Data transmission to remote facilities by email Nihon Kohden’s polaris.one data management system allows to view data at the hospital on a PC with ECG viewer software Self-test indicator that facilitates daily and monthly tests AC/battery operation Built-in thermal array recorder records variety of defi brillation information SD card for storage
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Charge fails or sluggish, low-energy delivery.
Root cause: Capacitor aging / leakage.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Won't charge or discharges unexpectedly.
Root cause: Relay/contactor wear.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical - keep charged spares.
Expiration-dated consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack Critical - keep charged spares. | Periodic replacement | $$$ | Fairly easy |
| HV energy storage capacitor | Major service part | $$$$ | Expert-level |
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
| Charge relay / contactor | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →