Natus · Model UltraPro S100
Efficiency: - 3 channel amplifier that allows for electrodes to remain in place, accommodating the most common modalities. - Triple programmable foot-switch supports hands-free operation. - Lightweight system that travels easily in a roller case or can be cart mounted. High Quality: - All-in-one electrodiagnostic system with dedicated controls. - Integrated stimulators. - Exceptional audio. - Low noise levels for exceptional signal quality. Exceptional Value: - Affordable equipment that meets your diagnostic and practice needs. - Includes instructional video, help menu, and training classes, virtually eliminating training expenses. Trouble-Free Installation: - 3 cables with unique connectors, so setup is easy. - No installation support is required. - Minimal set up time, allows you to start performing studies immediately. - On-screen help provides immediate assistance reducing the need for technical support. Ease of Use: - Simple user interface allows you to navigate through procedures quickly to reduce testing time. - The one-button EMR interface allows you to connect results more efficiently to electronic medical records. - Automatic reporting, online summaries, and built-in reference value database saves you time and generates reports faster.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Mains hum, drift or flat channels, persistently high electrode impedance, poor recording quality.
Root cause: Electrode / lead-wire wear, the electrode box (headbox) inputs, or poor skin prep / environment.
Symptoms: A block of channels dead or saturated regardless of electrode, calibration / bio-cal fails.
Root cause: Headbox amplifier or its cable to the acquisition unit.
Symptoms: Recording drops, amplifier not detected, data gaps.
Root cause: USB / fibre / network link or a driver.
Symptoms: Photic strobe not firing, no synchronised video, no audio.
Root cause: Photic lamp / trigger, the video camera, or the audio path.
Symptoms: A PSG channel (thermistor, pressure, RIP belt, SpO2, PLM) flat or noisy.
Root cause: Worn PSG sensor or its cable.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrode lead set / headbox leads | Frequent wear item | $$ | Easy |
| Headbox / amplifier | Major service part | $$$ | Moderate |
| Amplifier link cable / interface | Periodic replacement | $$ | Fairly easy |
| Photic stimulator lamp (diagnostic) | Periodic replacement | $$ | Fairly easy |
| PSG sensor set (airflow / effort / SpO2) | Frequent wear item | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.