Natus · Model Nicolet Ambulatory
• 34 active electrode inputs, 32 can be configured for referential recording, 16 can be configured for true bipolar recording • Combined with Nicolet's robust EEG software for review and NicVue, Nicolet's patient/data management sleep application, you can offer a complete comprehensive service to your patients • Easy-to-use software applications for spike and seizure, burst suppression, sleep, mapping, remote monitoring, remote control, central monitor and trends • Impedance checking capabilities • Glow-in-the-dark overlays • 9 auxiliary pairs (AC or DC) • Integrated SpO2 • High quality data • Rugged headbox design with quick disconnect • VLink/HL7 compatible • Support Connect compatible • Sleep auxiliary input box
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.