Mindray · Model Accutorr V
• Light weight, portable monitor with large bright LEDs easily read from any vantage point • Dedicated buttons for all primary functions promotes ease of use • The Accutorr V offers up to 9 hours of run time on one fully charged battery • Standard features include NIBP, SpO2, recorder, high resolution LCD display, pulse strength indicator, pulse waveform and a built-in power supply with lithium ion batteries • Highly visible alarm light enables instant visualization of alarm conditions • Easily configurable settings include patient size, interval time, alarms, inflation pressure, audio levels and temperature formats • Quick connect, single hose fittings • Unique flexible database stores up to 1200 readings instantly accessible by patient ID • With Accutorr CS Charting Solution software, wirelessly link the Accutorr V at the point-of-care to the clinician and to a hospital information system’s EMR
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →