MedTron · Model Accutron MR
Microprocessor controlled double-head injector with electric drive and two independent injection units. Multiphase, program controlled injection of contrast agent and physiological saline solution (NaCI) Aluminium housing. Motor, control and rechargeable batteries are integrated into a single compact unit Touch-screen control panel with different languages Additional keypad for manual piston movement, starting and stopping the injection Syringe holder with Easy Loading Syringe (ELS) 200 ml "Keep-Vein-Open" (KVO) feature Automatic power saving mode Non-stick syringe holder.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Will not arm, error message, aborts an injection.
Root cause: Air in the syringe / line, a syringe not seated, or a sensor / self-test fault.
Symptoms: Piston will not move, inaccurate flow or volume, stalls.
Root cause: Drive motor, leadscrew, or plunger engagement.
Symptoms: Injector disarms near the magnet or will not run out of the correct position.
Root cause: Tilt sensor or the MR-safety interlock.
Symptoms: No control from the console, status not updating.
Root cause: Cable, fibre link, or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Syringe drive motor / leadscrew | Major service part | $$$ | Difficult |
| Disposable syringe set | Consumable | $ | Easy |
| Hand / remote control | Periodic replacement | $$ | Fairly easy |
| Tilt sensor / MR interlock | Major service part | $$ | Moderate |
| Fibre / communication link | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio