Matachana · Model MAT LD500
The MAT LD500 washer thermodisinfector has the following qualities: Compact surface of only 662 mm x 1985 mm x 787 mm Up to 12 baskets of 1/1 DIN in 6 levels 15 liters of water per phase, reduced chemicals consumption Minimization of water and energy consumption, achieving cost savings per cycle and an increase in daily productivity Rack recognition and automatic cycle start using RFID wireless technology Dosing monitoring with flowmeters EasyRUN user interface and 7″ touch screen integrated in the front panel Door locking system that prevents simultaneous opening Ergonomic loading height Low noise level Installation under NULLGAP format, that allows to install up to 3 MAT LD500 washer thermodisinfectors in 2 meters wide Environmentally friendly thanks to the control of variables and cycle parameters that optimize the consumption of water, energy and chemicals
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →