BioDeviceHub

Sterilization

Autoclaves, sterilizers, washers

617 documented devices

Sub-types in this category

Where it is typically deployed

  • · Central Sterile Supply Department (CSSD)
  • · OR sterile core
  • · Satellite reprocessing areas

What a BMET must not skip

  • · A failed biological indicator means the entire load is not sterile - no exceptions, regardless of how the cycle printout looks.
  • · Door gasket wear is the most common real cause of a failed vacuum/pressure test - check it before deeper diagnostics.
  • · Water quality directly affects steam-cycle validity - don't ignore scale or mineral buildup.

Category-level clinical-engineering reference, general to this class of equipment, not verified against any one unit's own documentation.

Manufacturers with sterilization devices

Best-documented sterilization

Browse all 617
SciCan Statim 2000
SterilizationSterilizers/Autoclaves

SciCan Statim 2000

Statim 2000

SciCan

MELAG MELAtronic Series
SterilizationSterilizers/Autoclaves

MELAG MELAtronic Series

MELAtronic Series

MELAG

Midmark Ritter M11
SterilizationSterilizers/Autoclaves

Midmark Ritter M11

Ritter M11

Midmark

ASP Sterrad 100S
SterilizationSterilizers/Autoclaves

ASP Sterrad 100S

Sterrad 100S

ASP

Andersen Products Anprolene
SterilizationSterilizers/Autoclaves

Andersen Products Anprolene

Anprolene

Andersen Products

KSG 40/60
SterilizationSterilizers/Autoclaves

KSG 40/60

40/60

KSG

KSG 50/70
SterilizationSterilizers/Autoclaves

KSG 50/70

50/70

KSG

KSG 50/80
SterilizationSterilizers/Autoclaves

KSG 50/80

50/80

KSG

Midmark Ritter M7
SterilizationSterilizers/Autoclaves

Midmark Ritter M7

Ritter M7

Midmark

Midmark Ritter M9
SterilizationSterilizers/Autoclaves

Midmark Ritter M9

Ritter M9

Midmark

Tuttnauer EZ11 Plus
SterilizationSterilizers/Autoclaves

Tuttnauer EZ11 Plus

EZ11 Plus

Tuttnauer

ASP Sterrad NX
SterilizationSterilizers/Autoclaves

ASP Sterrad NX

Sterrad NX

ASP

Matachana S1000
SterilizationSterilizers/Autoclaves

Matachana S1000

S1000

Matachana

STERIS AMSCO Century
SterilizationSterilizers/Autoclaves

STERIS AMSCO Century

AMSCO Century

STERIS

Tuttnauer Valueklave 1730
SterilizationSterilizers/Autoclaves

Tuttnauer Valueklave 1730

Valueklave 1730

Tuttnauer

Amsco Reliance 570
SterilizationWasher/Decontaminator

Amsco Reliance 570

Reliance 570

Amsco

Arjo Typhoon
SterilizationWasher/Decontaminator

Arjo Typhoon

Typhoon

Arjo

Custom Ultrasonics System 83 Plus 2
SterilizationWasher/Decontaminator

Custom Ultrasonics System 83 Plus 2

System 83 Plus 2

Custom Ultrasonics

Getinge 400/500HC Series
SterilizationSterilizers/Autoclaves

Getinge 400/500HC Series

400/500HC Series

Getinge

Getinge 8666
SterilizationWasher/Decontaminator

Getinge 8666

8666

Getinge

HIRAYAMA HRG-112/ 140
SterilizationSterilizers/Autoclaves

HIRAYAMA HRG-112/ 140

HRG-112/ 140

HIRAYAMA

Lancer 1800LXA
SterilizationWasher/Decontaminator

Lancer 1800LXA

1800LXA

Lancer

Lancer 810LX
SterilizationWasher/Decontaminator

Lancer 810LX

810LX

Lancer

Lancer 815 LX
SterilizationWasher/Decontaminator

Lancer 815 LX

815 LX

Lancer