Lakeside · Model 8288BF-WW
Combination Warmer Independent temperature sensing system allows you to consistently provide the utmost in patient safety by remaining informed about exact fluid temperatures. Separate RTD probe for trusted accuracy and stability. Display shows the actual interior temperature (independently verified) versus the set temperature to quickly confirm proper operation. Dedicated microprocessor for a highly accurate PID temperature control and verification temperature sensing systems. Low-heat-density electrothermal warming provides efficient and even heating. Maintain safe (3 F of current setting), accurate temperature levels. Electronic control with LED display allows you to set and monitor temperature levels and lock settings to eliminate tampering. Two operating modes ensure safe temperature levels for irrigation fluids, 98-150 F (37-66 C), or injection fluids, 98-104 F (37-40 C). Separate safety override feature prevents overheating. Alarm alerts you if temperature changes 10 F (6 C) from current setting. Window door allows you to easily monitor inventory level. Heavy-duty stainless steel exterior provides durability and ease of cleaning and sanitizing. Heavy-duty handle and hinges withstand repeated use. White epoxy-coated wire baskets conveniently hold surgical fluids packaged in bags or bottles. Shown with optional.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Output below target, low-temperature alarm, slow warm-up.
Root cause: Heater plate(s) or the heater-control circuit, or a temperature-sensor fault.
Symptoms: The unit disables heating with an over-temperature condition (protects against haemolysis).
Root cause: Sensor or control fault driving the heater high, or an extreme flow-rate change.
Symptoms: Air-in-line alarm, flow stops.
Root cause: Air in the set, an improperly primed set, or an air-detector fault.
Symptoms: Set not detected, will not clamp / seat, leaks at the warming chamber.
Root cause: Worn set-detection switch or chamber fitting.
Symptoms: Cannot reach set flow, pressure alarm.
Root cause: Pump / roller fault or an occlusion.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Heater plate(s) / heater-control assembly | Periodic replacement | $$$ | Moderate |
| Temperature sensor | Major service part | $$ | Moderate |
| Air-detector / bubble sensor | Major service part | $$ | Moderate |
| Set-detection switch / chamber fitting | Periodic replacement | $$ | Fairly easy |
| Disposable warming set | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.