Lakeside · Model 8288BF
Combination Warmer Low-heat-density electrothermal warming provides efficient and even heating. Maintain safe (3 F of current setting), accurate temperature levels.Dual compartments each have user-friendly electronic control with LED display to set and monitor temperature levels and lock settings to eliminate tampering. Separate safety override feature prevents overheating.5″ heavy-duty casters, 2 with brake, for quickly transporting or storing close at hand. Window in door allows you to easily monitor inventory level. Heavy-duty stainless steel exterior provides durability and ease of cleaning and sanitizing. Heavy-duty door handle and hinges withstand repeated use. Blanket-warming compartment – Adjustable temperature range of 98-200 F (37-93 C) for maximum patient comfort. Automatic on/off setting to conserve energy. 1 blue, epoxy-coated blanket support assembly. Fluid-warming compartment -Two operating modes ensure safe temperature levels for irrigation fluids, 98-150 F (37-66 C), or injection fluids, 98-104 F (37-40 C). Alarm alerts you if temperature changes 10 F (6 C) from current setting. White epoxy-coated wire baskets conveniently hold surgical fluids packaged in bags or bottles.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No heat, or overheat alarm.
Root cause: Heater element or thermal cutoff failure.
Symptoms: Delivered fluid temperature out of set range.
Root cause: Inline/probe sensor aging or miscalibration.
Symptoms: False or missed air-in-line alerts.
Root cause: Air detector sensor drift or dirty optics.
Symptoms: Fluid leak, or won't prime.
Root cause: Worn cassette/tubing seat or cracked fitting.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Safety-critical; verify at PM.
Single-use consumable.
Consumable in some designs.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Air-in-line sensor Safety-critical; verify at PM. | Major service part | $$$ | Moderate |
| Disposable tubing / cassette set Single-use consumable. | Consumable | $ | Easy |
| Heating element / plate | Periodic replacement | $$$ | Moderate |
| Temperature sensor / probe Consumable in some designs. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →