Kinetec · Model Spectra S1
Shipping Weight & Dimensions: 38 lbs 41" x 17" x 14" Product: Weight 26 lbs (12kg) Product: Splint dimensions 37" x 13" x 13" (95 x 33 x 33cm); Product: Angular limits -10 to 120° Product: Speed from 40 to 145° per minute. Product: Patient height from 1.45 m (4' 9") to 1.95 m (6' 4") Product: Patient full leg from 71cm to 99cm (28” to 39”); Tibia from 38 to 53cm (15” to 21”); Femur from 33 to 46cm (13” to 18”) Product: With paediatric footplate option- patient full leg from 53cm to 109cm (21” to 43”); Tibia from 20cm to 56cm (8” to 22”); Product: Maximum user weight 135kg (298 pounds) Electrical: Power supply 100-240 V~ Electrical: Frequency 50-60Hz Electrical: Power consumption 20W Electrical: Device of type B Class 1 Electrical: IP 20 Storage/Transport Conditions: Temperature -40 to 70°C / -40 to 160°F Storage/Transport Conditions: Relative humidity up to 90% Operating Conditions: Room temperature 10 to 40°C (50 to 105°F) Operating Conditions: Relative humidity up to 80% Warranty: 2 Years
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unresponsive controls, won't power on.
Root cause: PSU or control board aging.
Symptoms: Loose joints, unstable frame.
Root cause: Fastener/bearing wear from repeated use.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power supply unit | Major service part | $$ | Moderate |
| Control panel / PCB | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →