Dynatronics · Model Solaris 700 Series
Electrotherapy Solaris Plus delivers up to 6 Stim waveforms including: IFC, Premod, Biphasic, Russian, High Volt, Microcurrent, and Fixed Frequency IFC/Premod. Solaris Plus has the power to deliver up to 5 channels of Stim, and a complete line of optional accessories - all at the same time. Soundheads As accessories for the Solaris Plus, Ultrasound soundheads are available in three sizes, 2 cm2, 5 cm2, and 10 cm2. One soundhead of your choice is included with the purchase of a Solaris Plus. 3-Frequency Ultrasound With the Solaris Plus you can select three different frequencies without changing the soundhead. The 2 cm2, 5 cm2, and 10 cm2 soundheads each operate at 1, 2, and 3 MHz, providing the greatest flexibility in depth of treatment. SmartHead Technology The Solaris Plus features SmartHead technology, having all calibration information stored within the soundhead. Each soundhead plugged into the device will be uniquely recognized and ready to use. Target & Target Sweep Solaris Plus’ unique TARGET feature produces a more effective interferential treatment by allowing the treatment to be focused precisely where it is needed. Simply glide your finger across the TARGET touch pad to move the center of interference to the site of your patient’s pain. Optional Battery The Solaris Plus may be operated with power supplied by an external 12-volt battery (not included), offering greater flexibility and portability in treatment sites. Solaris Plus Cart The Solaris Plus Cart provides ample storage space with three large drawers. Constructed with a low center of gravity to prevent tipping, the Solaris Plus Cart is sturdy and aesthetically pleasing.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Ultrasound, e-stim, shortwave or laser channel delivers no or weak output, error on that channel, patient feels nothing.
Root cause: Applicator / electrode / handpiece fault, a lead / cable fault, dried electrodes, or an output-stage fault on that module.
Symptoms: Low or no ultrasound output, applicator-contact / BNR error, no warmth on a water-bath test.
Root cause: Worn or cracked applicator crystal, or a cable fault.
Symptoms: Intermittent stim, open-circuit error, uneven sensation.
Root cause: Worn lead wires or exhausted / dried self-adhesive electrodes.
Symptoms: Unresponsive or erratic touchscreen, parameters will not set.
Root cause: Touchscreen or controller fault.
Symptoms: Will not power on, short battery life, or shuts down on temperature.
Root cause: Power supply / fuse, an aged battery, or a cooling-fan fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Therapeutic-ultrasound applicator | Periodic replacement | $$ | Easy |
| Electrotherapy lead wires | Frequent wear item | $ | Easy |
| Self-adhesive / carbon electrodes | Consumable | $ | Easy |
| Output board / module | Major service part | $$$ | Difficult |
| Touchscreen / control assembly | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.