Invivo · Model Magnitude 3155A
The Leader in MRI Patient Monitoring INVIVO MAGNITUDE MRI Vital Signs Monitor provides the operator with ECG, Respiration, SpO2, NIBP, EtCO2 and Optional Invasive Pressures monitoring. Full control of patient monitoring is provided via the INVIVO Millenia 3155A Monitor equipped with MRI shielding and set to Remote Communication Mode. Among other features the Magnitude 3150M MRI Monitor includes "Digital Signal Processing" (DSP) and an "MRI View Mode". DSP provides improved ECG performance and reduction of MRI gradient artifact. The "MRI View Mode" provides Adaptive ECG Gradient Filtering techniques for enhanced ECG display during MRI sequences. Every feature of the 3150M is synchronized via wireless 2.4 Ghz technology with the remote monitor which means this unit is portable and requires no expensive installation. Invivo was recently aquired by Phillips and is the global leader in MRI monitoring technology.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →