Intermedical · Model Submarine
SUBMARINE is composed of a ceiling suspended X-ray tube, a floating table-top with adjustable height and a multifunctional -20°/+90° tilting Bucky stand. It can be equipped, according to clients’ needs, with a single or double digital FPD: tethered 43x43 and/or wi-fi 43x36. Deluxe acquisition and processing software guarantees high image quality, thanks to processing filters and LUTs specific for each examined anatomical region, patient dose reduction, pre-set anatomical programs and customizable protocols as well as the ability to reconstruct the images acquired through the stitching function. SUBMARINE is equipped with both manual and automatic movements (APP Automatic Programmed Positioning). Through an extremely intuitive interface it is possible to automatically position the system according to the type of exam and projection to be performed. Auto-tracking allows the operator to align the movements of the X-ray tube and the detector automatically. Equipped with an on-board Touch panel, it is possible to view all the operating parameters and manage system’s movement
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →