Hospira · Model Lifecare PCA Mednet
Drug Recognition: • Built-in bar code reader automatically identifies drug name and drug concentration in the vial of all prefilled Hospira vials. The bar code reader can recognize custom-filled vials of pharmacy-generated barcodes when Hospira MedNet software is enabled. Programming: • Designed to help reduce medication errors, enhance utility and increase efficiency • Prompting alphanumeric display • Review screen confirms data input before infusion begins • Auto-programming available easy use Biomedical: • RJ-45 Ethernet connector • Software is field upgradeable • Diagnostic setup options • Alarm history • Stored speed protocol function for Hospira prefilled vials and custom (sterile empty) vials • Nurse call relay connector • Infusion history Other Features: • Various Modes of Delivery: PCA only, Continuous, and PCA + Continuous • Wireless antenna • Microprocessor control • LCD and LED display • Back panel illumination • Security features • 8 V battery for emergency backup and temporary portable operation (approximately 3 hours)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Stalled infusion, inaccurate rate.
Root cause: Peristaltic motor or encoder wear.
Symptoms: Set not recognized, door-open error.
Root cause: Dirty or failed door microswitch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Common R&R on high-mileage pumps.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic roller / pump mechanism Common R&R on high-mileage pumps. | Periodic replacement | $$$ | Difficult |
| Air detector / ultrasonic sensor | Periodic replacement | $$ | Moderate |
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →