GE HealthCare · Model Solar 8000i
Modular monitoring for critical care [list] [b]Advanced monitoring developed with clinicians for clinicians[/b] [*] High-acuity patient monitoring system that enhances clinical decision making with a constant availability and flow of information [*] iTouch-screen intuitive and easy to learn user interface provides fast access to the information you need to gain a full understanding of your patient [*] Cost-effectively adapts to a broad range of care needs in multiple care environments [*] Offers a comprehensive selection of measurements. From the Tram multi-parameter to specialty measurement modules for all clinical applications allowing you to choose and configure the parameters to match your patient needs [*] Integrates third-party devices’ numeric data, waveforms and alarm information onto the monitor, the network and central stations [b] Flexibility and ergonomics make the care easier[/b] [*] Choice of flat panel displays to help you easily configure the system to meet your needs [*] Care unit specific remote controls provide easy one-button access to commonly used functions [*] Powerful Tram multi-parameter modules provide uninterrupted monitoring during patient transfer with full data continuity including information from additional specialty measurement and from connected external devices [*] Exceptionally easy to use touch-screens and consistent menu structures enhance usability [*] Vertical split screens allow to view two patients simultaneously without any loss of information [*] View on alarms (VOA) allows clinicians to remotely view user designated bedside monitors and user selected alarms and patient information [*] Remote iTouch Pad for easy access saving time and effort [/list]
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature, CO2 or CO intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a parameter-module / input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: The host does not display a plugged-in module or a built-in parameter.
Root cause: Docking / connector fault or an internal board fault.
Symptoms: Blank, dim or distorted display; unresponsive touchscreen.
Root cause: Display, backlight, or controller fault.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack or a power-supply fault.
Symptoms: Monitor not shown at the central station, admit fails, intermittent drop.
Root cause: Wired / Wi-Fi network configuration or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Parameter module / input board | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Display / touchscreen assembly | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.