GE HealthCare · Model CARESCAPE V100
Accuracy The CARESCAPE V100 provides precise, accurate readings using proven DINAMAP technology. The GE DINAMAP SuperSTAT blood pressure algorithms support speed, comfort and artifact rejection for virtually all types of patients, including neonates with very low perfusion pressures, geriatrics and hyper/hypo tensive patients. When combined with the Mobile Vitals Plus application, vital signs are transmitted to the EMR in real time, eliminating any transcription errors. Speed With non-invasive blood pressure determination times as fast as 14 seconds, and the clinical accuracy of embedded DINAMAP technology, the CARESCAPE V100 monitor delivers exceptional speed and accuracy. The Exergen TemporalScanner thermometer provides non-invasive, fast, easy and accurate temperatures. And when combined with the Mobile Vitals Plus application, vital signs are transmitted to the EMR in real time, eliminating any lag time. Efficiency The CARESCAPE V100 monitor is a two-in-one monitor - it can be used for both spot check and continuous monitoring, with continuous monitoring freeing up valuable nursing time. When combined with the Mobile Vitals Plus application, nurses spend less time in documentation and more time with their patients and families. Infection Prevention GE supports your infection prevention efforts. They offer the Exergen TemporalScanner thermometer, which does not come into contact with mucous membranes. In addition, the silver ion anti-microbial head has been found to reduce the population of Staph, Listeria and E-Coli. The monitor’s durable plastic coating is compatible with most stringent chemical hospital cleansers, and GE CRITIKON blood pressure cuffs are disposable. Mobility Not only can it withstand the rigors of tough clinical use and cleaning, the CARESCAPE* V100 monitor’s battery has a long run time – typically eight to 11 hours before requiring recharge. And if the battery is discharged, it maintains the data, and users can plug it in and continue to use the monitor. This extended battery life allows users to flexibly move the monitor from one patient room to the next for the course of a shift. Consistent across all care areas The CARESCAPE* V100 includes the same advanced parameters and algorithms as other higher acuity GE monitors, so users can consistently measure across all care areas – from the ED to OR to ICU to PACU to Surgical. This gives users confidence that when a patient’s measurements deviate, the change is due to the patient’s condition - not a difference between monitors. With speed, accuracy and connectivity, the CARESCAPE V100 monitor, along with the Mobile Vitals Plus solution1, helps users manage Clinical Information Logistics by collecting the right information at the point of care, and presenting it wherever it is needed. So users can make fast, quality care decisions informed by relevant, current clinical intelligence.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
High-turnover; keep inventory.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.