Fanem · Model Heater Box 1502
Digital control panel with temperate settings from +5°C of the environment to 60°C, with 0.1°C resolution Thermostatic accuracy from +/- 0.7°C at 37°C Temperature preset at 37°C, controlled by a digital sensor, with internal circulation of heated air generated by a tangential fan with a capacity of 150 m3/h in order to ensure better uniformity Uniformity of +/- 1.5°C, at a temperature of 37°C Easy-to-replace, modular heating element Electronic safety thermostat with a chip that is separate from the control system; automatically shuts down the heating system and issues a visual warning on the panel Control panel with LEDs which visually indicate the current temperature and heating, with increase and decrease keys and a key for setting parameters High temperature digital alarm that is totally separate from the temperature control, with audible and visual indication Safety switch which stops air circulation and heating when the lid is open and re-establishes normal operation when the lid is closed.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No heat, or overheat alarm.
Root cause: Heater element or thermal cutoff failure.
Symptoms: Delivered fluid temperature out of set range.
Root cause: Inline/probe sensor aging or miscalibration.
Symptoms: False or missed air-in-line alerts.
Root cause: Air detector sensor drift or dirty optics.
Symptoms: Fluid leak, or won't prime.
Root cause: Worn cassette/tubing seat or cracked fitting.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Safety-critical; verify at PM.
Single-use consumable.
Consumable in some designs.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Air-in-line sensor Safety-critical; verify at PM. | Major service part | $$$ | Moderate |
| Disposable tubing / cassette set Single-use consumable. | Consumable | $ | Easy |
| Heating element / plate | Periodic replacement | $$$ | Moderate |
| Temperature sensor / probe Consumable in some designs. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →