Fanem · Model Heamto-Immuno EBS 3347
Automatic defrosting system, with evaporation of condensation Condensation tank is removable to enable sterilization in accordance with quality and safety standards Forced air circulation results in perfect homogenization within the chamber Fan operates even when batteries are used, ensuring uniformity in any system Easy-to-view LCD display and real-time LED indicators of the status of the auxiliary battery Digital thermometer with 0.1oC subdivision of readings, and maximum and minimum temperatures read directly and simultaneously on the same display Menu for multiple sensors, which enables simultaneous viewing of the temperature in all installed sensors Audible and visual alarms for open door, pre-programmed low and high temperatures and EBS status at 2oC and 8oC, respectively; can be adjusted manually at other temperatures Alarm testing system for simulation of low and high temperature alarms Operating temperature: 2oC to 8oC, memorized at 4oC Internal capacity: 120 liters/9,100 5-ml doses DAQ (Data Acquisition) - registers data in memory for up to 10 days, allowing for subsequent consultation of temperature variations.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The patient warming is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio