Ergoline · Model Ergoselect 4
Quality you can count on The completely new ergometer series from ergoline brings functionality, technology and design to a whole new level. With a unique variety of variants and technical details, the ergoselect 4 can be perfectly matched to every application situation.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Measured power does not match the set point, resistance feels wrong or absent, load errors during a stress test.
Root cause: Eddy-current brake or its control board out of calibration, or a tacho/speed-feedback fault.
Symptoms: Rumble, knocking or uneven resistance while pedalling.
Root cause: Worn drive belt, crank bearing or freewheel.
Symptoms: ECG or exercise system does not see the ergometer, no remote load control.
Root cause: RS-232/analogue/digital interface cable or the ergometer control board.
Symptoms: NIBP readings fail or are implausible during exercise.
Root cause: Pump, valve or cuff/hose leak in the integrated BP module.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Eddy-current brake unit | Major service part | $$$ | Difficult |
| Drive belt | Periodic replacement | $ | Moderate |
| Crank bearing set | Major service part | $$ | Difficult |
| Control PCB | Major service part | $$$ | Moderate |
| Interface cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio