Defibtech · Model Lifeline View
A Personal Coach - The Lifeline VIEW has a built-in metronome that counts out the beat of the compressions to provide so you know what to do and when to do it Real-Time Protocol Selection - Allows you to switchover from compression-only CPR to compression and rescue breathing CPR without skipping a beat Ruggedness & Durability - The VIEW's ruggedness is measured by demanding environmental tests Easy to Maintain - The status screen gives you up to the minute information on maintenance if it's required Device Ready for Rescue - Lifeline VIEW's one touch status screen gives you everything you need to know that the unit is up to date and in working order without turning it on
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Charge fails or sluggish, low-energy delivery.
Root cause: Capacitor aging / leakage.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Expiration-dated consumable.
Critical - keep charged spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
| Charge relay / contactor | Periodic replacement | $$$ | Difficult |
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical - keep charged spares. | Periodic replacement | $$$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
A component of a sub-assembly used in the affected AEDs had not undergone durability and reliability testing, and if a malfunction occurs, therefore the device could fail to deliver therapy.
A component issue may cause the AED to abort a shock delivery or reset unexpectedly, which may cause an affected device to fail to delivery shock, and/or to fail to deliver shock in range.
Software with version 2.004 software or earlier may cause an affected AED to cancel shock during the charging process
The AED when used with an affected battery pack, may falsely detect an error condition, cancel charge and not provide therapy
Device Malfunction-The self-test software may allow a self-test to clear a previously detected low battery condition. If this occurs, the operator may be unaware of the low battery and the device may be "unable" to deliver a defibrillation shock, which could result in failure to resuscitate a patient.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.