Datascope · Model Trio
8.4” color TFT display with an 800 x 600 resolution provides optimal visualization of patient data. Standard features include 4 waveforms, 3 or 5 lead ECG, Respiration, NIBP, SpO2, and Temperature. Various options include Masimo SET® motion tolerant SpO2, Nellcor® OxiMax® SpO2, Invasive Blood Pressure, Lithium Ion battery and a two-trace, integral recorder. Full graphic and list trends of all monitored parameters, provide instant recall of patient data. Five-color display of waveform and numeric data enables quick and easy recognition of patient information. Default menu allows for storage and retrieval of user configured settings for each patient size. Ergonomically designed fold-away handle with built-in bed rail hook provides maximum flexibility and easy handling. Front panel keypad, featuring the Navigator™ Control Knob and quick action keys, allows for one-step action of essential functions. Conveniently located alarm light enables instant visualization of alarm conditions. Built-in Power Supply for direct AC connection allows for convenient transport from one location to the next.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature, CO2 or CO intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a parameter-module / input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: The host does not display a plugged-in module or a built-in parameter.
Root cause: Docking / connector fault or an internal board fault.
Symptoms: Blank, dim or distorted display; unresponsive touchscreen.
Root cause: Display, backlight, or controller fault.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack or a power-supply fault.
Symptoms: Monitor not shown at the central station, admit fails, intermittent drop.
Root cause: Wired / Wi-Fi network configuration or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Parameter module / input board | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Display / touchscreen assembly | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Software anomaly where the variable heart rates may be displayed inaccurately or intermittent 'dashes' may be displayed when the patient's heart rate is derived from ECG.
The Trio Monitor has latex feet. It is not labeled per 21 CFR801.437 to indicate that it contains latex.