Datascope · Model 97E
Analyses cardiac interval patterns Automatic selection of R-Wave deflation Reliable A-Fib tracking Rapid QRS identification Improved Arrhythmia Management.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Poor or no diastolic augmentation, abnormal balloon-pressure waveform, gas-loss / leak alarm.
Root cause: Balloon-catheter leak or kink, a loose connection, or low helium.
Symptoms: Pump not triggering or mistimed, inflation / deflation off the cardiac cycle.
Root cause: Poor ECG or arterial-pressure trigger (electrodes, cable, lead selection), or a timing issue.
Symptoms: Autofill fails, cannot maintain balloon volume, drive alarm.
Root cause: Helium cylinder low, a solenoid / compressor fault, or a pneumatic leak.
Symptoms: Short transport battery run time, unresponsive touchscreen.
Root cause: Aged battery packs or a display / control fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Helium cylinder | Frequent wear item | $ | Fairly easy |
| Battery packs | Periodic replacement | $$ | Fairly easy |
| Safety chamber / disposable extension tubing | Consumable | $ | Easy |
| Solenoid valve / drive components | Major service part | $$$ | Difficult |
| Touchscreen / control-panel assembly | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.