das · Model AP BLOT
2 external washing tanks and 1 external waste tank, each equipped with level sensors. Strip vessels Six trays for 8 strips each, alloted on a shaker. Processing From 1 to 48 strips. Strip washing Aspirate and dispense liquid through out the two instrument probes. Dispensing system One aspirate probe and one dispense probe (XYZ movement). Dispense volume Up to 2500 µl by 1 µl resolution. Imaging acquisition High resolution Colour Camera mounted on moving Z group. Operating Functions The system can manage up to 10 method on the same run. Definition of incubation times and volume to dispense for sample and reagents. Different incubation times for each method Easy and fast settings for new protocols. Setting for the kind of strip to process. Automated Blot assessment and report. Software requirements User friendly software. Operating systems to set up the working list, patient reports and result storage. Host computer interface (LIS). Windows XP and 2000 operating system.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The medical imaging is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.