Contec Healthcare · Model CMS 7000 Plus
• Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user. • Be applicable for adult, pediatric and neonatal. • Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, built-in printer, curving handle, moving bracket and hanging bracket are optional. • Finish all operations by touch screen or keys and knobs. • Operation interface with Chinese and English. (Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance. • 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously. • Monitoring contents, scan speed, volume and output contents can be set optionally. • Storage of 480-hour trend data, and review of 40-second holographic waveform. • Storage and review of 72-hour ECG waveform. • Function of NIBP review, storage for up to 2400 NIBP data. • Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability. • Calculation of drug concentration. • Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired. • Built-in rechargeable battery for uninterrupted monitoring. • Print ECG, SpO2, RESP, BP and temperature data with one-key.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →