Carestream · Model DirectView DR 9500 System
Rotation around the patient provides easy access to any projection with c-arm ease. Ergonomic work zone design created with extensive radiographer input for focus on productivity. Single ceiling mounted arm allows exposure from right to left or left to right with equal ease. The flexibility of a dual detector system in a unique, single detector design. Dual on board touch screen displays complement the exposure console allowing technique and other exposure setting to be adjusted while the radiographer is with the patient from a choice of two different strategic positions around the patient. Motorized positioning allows rapid movement with minimal operator fatigue, keep productivity high for an entire shift. Remote control saves steps and allows positioning of system from most convenient locations. Auto-positioning can be used to link pre-defined positions to hundreds of procedures. State of the Art 43cm x 43 cm detector with 143 x 143 micron pixel size with Cesium Iodide capture technology. Clinically tested at 400-speed screen-film equivalent exposures. Wide dynamic range - 14-bit data captured, with excellent DQE and MTF characteristics.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Panel not detected, images not received, wireless / tethered link drops mid-exam.
Root cause: Detector battery (wireless), Wi-Fi / tether cable, a docking / connector fault, or detector electronics.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead pixels / lines, calibration overdue or failing.
Root cause: Detector gain / offset calibration, a bad pixel map, or physical detector (drop) damage.
Symptoms: Exposure inhibited, kV / mAs error, no exposure captured, AEC over/under.
Root cause: HV generator, tube, filament supply, or an AEC / interface fault.
Symptoms: Tube column, wall stand or table bucky will not track, detent, or auto-position.
Root cause: Drive motor, brake, encoder, or the auto-positioning interface.
Symptoms: Images will not display, process or send; worklist missing; slow processing.
Root cause: Workstation PC, software, or the DICOM / network configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Moderate |
| Detector battery (wireless) | Periodic replacement | $$ | Easy |
| Tether cable / access point | Periodic replacement | $$ | Fairly easy |
| Positioner drive / brake / encoder | Major service part | $$$ | Difficult |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
| AEC ion chamber | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.