Biocare · Model iM 12 Multi-Parameter Patient Monitor
12.1 inches high resolution color TFT display Optional full touch-screen for easy operation Attractive and durable silicon buttons with backlight Optional 12-lead ECG accurate analysis and further diagnostic confirmatiom S-T segment analysis and 23 types of arrhythmia analysis Maximum 480-hour graphic and tabular trends, 1000 NIBP records, 700 alarm events and 2-hour ECG waveform storage and review Large font display, OxyCRG, graphic & tabular trends, bed-bed observation and more display modes to meet different needs in clinics care 5 kinds of calculations: medication calculation, hemodynamic calculation, renal function calculation, oxygenation calculation and ventilation calculation ESU proof and defibrillation synchronization for different working environments Rechargeable Li-ion batteries for up to 10 hours of continuous work USB port enables software upgrade and also supports external USB storage Selectable color configurations for all parameters (32 colors) VGA output for external display (optional) Flexible mounting and trolley solution (optional) Wire/wireless network connect to central monitoring system (optional)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Immunohistochemistry device kits found to display incorrect staining pattern due to mislabeling of two components.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →