Alcon · Model INFINITI
Anticipating Every Move. Now that’s Smart. Now featuring OZil Intelligent Phaco software upgrades, the INFINITI Vision System puts optimized OZil torsional emulsification at your fingertips. With enhanced fluidic management and surgical control, the INFINITI Vision System delivers the strategic advantage in customized phaco procedures.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
High-value, track usage.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Alcon is conducting a medical device recall due to the possible presence of pieces of tubing in the aspiration line.
The recalling firm received complaints related to leakage from the tubing near the white luer of the irrigation line for the INFINITI Ultrasound Packs.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →