AGFA · Model DR 800
Full Leg/Full Spine capabilities come standard, including tube and detector positioning, acquisition of up to four images. With EasyStitch™, you can add extensive orthopedic tools. Seamless automatic stitching directly on the table allowing horizontal and vertical Full Leg/Full Spine (FLFS) procedures. EasyStitch uses single focus, distortion free imaging technology providing simple, precise Full Leg/Full Spine (FLFS) imaging. Implementing the DR 800 with digital tomosynthesis will add a key new tool to your imaging portfolio: one that gives your hospital’s radiologists more choices than found in legacy equipment. By using multislice image reconstruction, the DR 800 provides the depth to see beyond dense structures, revealing more details than classical X-rays. Yet it uses the low radiation dose and fast workflow of general radiography. The DR 800 offers improved diagnostic visualization for interventional procedures, with real-time subtraction and masking (roadmapping) for guidance in the positioning and placement of catheters, stents and balloons.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
It is possible to exceed the maximum allowed Air Kerma rate (AKR) of 88mGy/min for pulsed fluoro exams. This can happen in case the framerate is increased on the NX workstation when ABS is not enabled.
Potential for the front lever chain of the DR 800 table to fail.
Under specific conditions (Fluoroscopic exam, ABS=OFF, manual change of parameters) wrong calculation of the dose/minute for fluoroscopy exams can be possible
Tomosynthesis image acquisition sequence did not stop automatically after expected number of exposures.
The exposed area of fluo exams possibly does not match the active area of the detector within specified limits.