ZEISS · Model CIRRUS HD-OCT
Spot small areas of pathology - tightly spaced B-scans, (either 30 or 47 µm apart), in the cube ensure that small areas of pathology are imaged Visualize the fovea - scans that are spaced further apart than in the CIRRUS cube may miss the central fovea Fuel for analysis - millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis Take the pressure off the operator - as long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture See the tissue from different perspectives - view the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™ Future-ready - previously captured CIRRUS cubes can be analyzed using new analyses.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or dim fluoro, dose creep, poor DSA, ABC not tracking.
Root cause: Flat-panel detector degradation or the dose / image-processing chain.
Symptoms: Fluoro or cine inhibited, generator error code, tube-arc faults.
Root cause: HV generator, the X-ray tube, or the filament supply.
Symptoms: Gantry will not angulate, rotate or reach a stored position; collision trips.
Root cause: Positioner drive, encoder, brake, or collision sensors.
Symptoms: Table float, tilt, height or cradle will not respond; tableside module dead.
Root cause: Table drive, the tableside control module, or its cable.
Symptoms: Pressures / ECG missing on the hemo system, injector arm / interface fault.
Root cause: Hemo transducer inputs, the recording PC, or the injector interface.
Symptoms: Fluoro / cine inhibited after a run, tube-heat alarm.
Root cause: Tube heat limit or a heat-exchanger fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| X-ray tube assembly | Periodic replacement | $$$$ | Expert-level |
| HV generator components | Major service part | $$$$ | Expert-level |
| Positioner drive / encoder / brake | Major service part | $$$ | Difficult |
| Table drive / tableside control module | Major service part | $$$ | Difficult |
| Heat exchanger / cooling components | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.