Toshiba · Model Infinix CF-i/SP
• Uncompromized patient access - The Infinix CF-i/SP brings revolutionary flexibility to floormounted X-ray systems. The unique design enables operators to move the C-arm around the exam table as needed to obtain the optimal angle for cardiac and general angiography. This imaging system features an 8-inch flat panel detector that delivers outstanding image quality. • Outstanding imaging capability - Infinix CF-i/SP acquires outstanding images for cardiac angiography by utilizing Toshiba’s high-definition flat panel detector. To speed throughput, the system features real-time image processing. To help clinicians manage dose, the system images at a wide range of frame rates. • 3D DetectionTime saving technologies - Infinix CF-i/SP is equipped with Sequential Navigation. When a physician needs to quickly “navigate” through an exam, the system can duplicate preferred angles, projections and acquisition parameters with the touch of a button. Parameters can be changed as needed, without disrupting Sequential Navigation throughout the procedure.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →