AccuVein · Model AV400
Vein viewing system The AccuVein digitally displays a map of the vasculature on the surface of the skin in real time, allowing clinicians to verify vein patency and avoid valves or bifurcations. It is handheld and lightweight, weighing only 9.7 ounces (275g), and easily converts to hands-free with the use of optional wheeled or fixed stands. The medical grade design allows the device to be easily wiped clean, bagged for use in isolation, and does not require calibration as it is permanently aligned. The easy to use AV400 can be held in any direction above the vein being viewed. Universal and inverse modes make the AccuVein useful on a variety of patient types. With center line accuracy to the width of a human hair, the AccuVein can detect veins up to 10 mm deep. More effective venipuncture procedures with less patient discomfort result in higher patient satisfaction, making it clear why many facilities have chosen to incorporate AccuVein into their standard of care.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or dim fluoro, dose creep, poor DSA, ABC not tracking.
Root cause: Flat-panel detector degradation or the dose / image-processing chain.
Symptoms: Fluoro or cine inhibited, generator error code, tube-arc faults.
Root cause: HV generator, the X-ray tube, or the filament supply.
Symptoms: Gantry will not angulate, rotate or reach a stored position; collision trips.
Root cause: Positioner drive, encoder, brake, or collision sensors.
Symptoms: Table float, tilt, height or cradle will not respond; tableside module dead.
Root cause: Table drive, the tableside control module, or its cable.
Symptoms: Pressures / ECG missing on the hemo system, injector arm / interface fault.
Root cause: Hemo transducer inputs, the recording PC, or the injector interface.
Symptoms: Fluoro / cine inhibited after a run, tube-heat alarm.
Root cause: Tube heat limit or a heat-exchanger fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| X-ray tube assembly | Periodic replacement | $$$$ | Expert-level |
| HV generator components | Major service part | $$$$ | Expert-level |
| Positioner drive / encoder / brake | Major service part | $$$ | Difficult |
| Table drive / tableside control module | Major service part | $$$ | Difficult |
| Heat exchanger / cooling components | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.