XPXvivo Perfusion AB · Model 19030
The XVIVO Perfusion System (XPS™) is indicated for use in flushing and temporary continuous normothermic machine perfusion of initially unacceptable excised donor lungs during which time the ex-vivo function of the lungs can be reas-sessed for transplantation.
Intended use: An assembly of devices designed to be used for the reconditioning, ex-vivo evaluation and cold preservation of donated lungs prior to transplantation. It typically consists of a mains electricity (AC-powered) unit which includes an operator's console, a roller pump, monitor, heat exchanger unit and gas system. The lungs are placed in a disposable chamber where they are connected, via tubing, to the evaluation unit. Typically, measurements can be made of pulmonary pressure, temperature, and flow, with calculation of pulmonary vascular resistance. The system is intended for use in a hospital in a clean area and is mobile on wheels.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Perfusate flow error, pump will not reach the set flow, occlusion or pressure alarm.
Root cause: Centrifugal / roller pump head wear, a kinked circuit, or a drive / control fault.
Symptoms: Post-membrane blood-gas targets not met, sweep-gas fault.
Root cause: Oxygenator clotting or fibre wetting, or a gas blender / supply fault.
Symptoms: Perfusate temperature not reaching or holding the target, heater / cooler alarm.
Root cause: Heater-cooler unit, tubing, or a temperature-sensor fault.
Symptoms: Lung ventilation pressures or tidal volume off target, ventilator alarm.
Root cause: Integrated ventilator fault or a circuit leak.
Symptoms: Pulmonary artery pressure, LA pressure or flow reads implausibly.
Root cause: A transducer drifted or a wetted protector.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Pump head | Periodic replacement | $$$ | Difficult |
| Membrane oxygenator (disposable circuit) | Consumable | $$$$ | Easy |
| Heater-cooler components | Major service part | $$$ | Difficult |
| Pressure / flow transducers | Periodic replacement | $$ | Moderate |
| Disposable perfusion circuit / tubing pack | Consumable | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.