Winco · Model 6570
Standard headrest cover. Padded drop-down armrests. Dual fold down side-tables. Easy-to-clean side panels. Trendelenburg Positioning.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Height / back / tilt does not respond to the hand or foot control.
Root cause: Foot / hand control fault, a linear actuator, a control-box relay, or a limit switch.
Symptoms: Table settles under load after positioning.
Root cause: Actuator backdrive or a gas-spring fault.
Symptoms: Intermittent or dead hand / foot control.
Root cause: Cable, contacts, or fluid ingress.
Symptoms: Rumble or sluggish travel.
Root cause: Worn actuator or unlubricated joints.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Linear actuator | Major service part | $$$ | Moderate |
| Hand / foot control | Periodic replacement | $$ | Fairly easy |
| Control box / relay | Major service part | $$$ | Moderate |
| Gas spring (back assist) | Major service part | $ | Moderate |
| Limit switch | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Winco Manufacturing LLC is recalling the Care Cliner, XL Care Cliner, Drop Arm Care Cliner, Elite Care Cliner, and XL Elite Care Cliner chairs with nylon casters distributed between 04/01/2009 and 08/31/2009. Certain 5" nylon casters shipped with the chairs may be defective. There is a potential of the caster's axle working itself out of the assembly under unconventional conditions. Should this
Winco Mfg., LLC, Ocala, Florida is recalling their Care Cliner. Due to malfunctioning axles which become lose from the caster assembly. This chair is a multi position recliner with a steel frame used primarily in clinics, hospitals and treatment centers for recovery, dialysis, oncology, examination, infusion. Recalled chairs include the following: Care Cliner, XL Care Cliner, Drop Arm Care Cliner