5020 Power Procedure Table Our most economical, yet fully featured power procedure table, the UMF Medical lowers to a height of 24 inches (61.0cm)from the floor in a reassuring upright chair position. Provides the versatility needed for OB/GYN, dermatology, proctology, minor surgery and urology procedures and exams. The one-touch, four function hand control allows for precise, smooth operation. You can quickly and easily adjust the seat height, tilt angle, backrest angle, and leg section height with the push of a button. A four function programmable foot control is also available for truly hands-free operation. The UMF Medical Ultra Comfort Seamless Top provides security and comfort for patients and also allows for easy cleaning and helps prevent cross-contamination.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Height / back / tilt does not respond to the hand or foot control.
Root cause: Foot / hand control fault, a linear actuator, a control-box relay, or a limit switch.
Symptoms: Table settles under load after positioning.
Root cause: Actuator backdrive or a gas-spring fault.
Symptoms: Intermittent or dead hand / foot control.
Root cause: Cable, contacts, or fluid ingress.
Symptoms: One-touch stirrups or the leg section will not glide or lock.
Root cause: Worn stirrup track or leg-section pivot.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electro-mechanical actuator | Major service part | $$$ | Moderate |
| Hand / foot control | Periodic replacement | $$ | Fairly easy |
| Control box / relay | Major service part | $$ | Moderate |
| Back gas spring | Major service part | $ | Moderate |
| Stirrup / leg-section hardware | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.