Toshiba · Model Infinix-i Sky+
Features a double sliding C-arm and 12x16 flat panel. Imaging soars to even greater heights with an innovative C-arm flip, lateral flexibility, speed, and full body 3D imaging capability. Infinix-i Sky + offers revolutionary ImagingRite technology to generate a 3D image anytime, anywhere. Fast peripheral access without moving patient or table. 270 degree C-arm rotation. Variable C-arm positions. Automatic synchronization of detector and collimator for correct heads up display, regardless of C-arm position. Save space by simply flipping the C-arm into AP orientation during procedures such as long-needle biopsies. 3D digital subtraction angiography (DSA), 3D digital angiography (DA), and low contrast imaging (LCI) can now be performed from the patient head on the left or right side for enhanced efficiency and flexibility. 3D DA and 3D DSA can be performed from either side of the patient with the C-arm traveling 210 degrees at 80 degrees/sec providing the option for very fast acquisitions with high image quality.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or dim fluoro, dose creep, poor DSA, ABC not tracking.
Root cause: Flat-panel detector degradation or the dose / image-processing chain.
Symptoms: Fluoro or cine inhibited, generator error code, tube-arc faults.
Root cause: HV generator, the X-ray tube, or the filament supply.
Symptoms: Gantry will not angulate, rotate or reach a stored position; collision trips.
Root cause: Positioner drive, encoder, brake, or collision sensors.
Symptoms: Table float, tilt, height or cradle will not respond; tableside module dead.
Root cause: Table drive, the tableside control module, or its cable.
Symptoms: Pressures / ECG missing on the hemo system, injector arm / interface fault.
Root cause: Hemo transducer inputs, the recording PC, or the injector interface.
Symptoms: Fluoro / cine inhibited after a run, tube-heat alarm.
Root cause: Tube heat limit or a heat-exchanger fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| X-ray tube assembly | Periodic replacement | $$$$ | Expert-level |
| HV generator components | Major service part | $$$$ | Expert-level |
| Positioner drive / encoder / brake | Major service part | $$$ | Difficult |
| Table drive / tableside control module | Major service part | $$$ | Difficult |
| Heat exchanger / cooling components | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.