Thermo Scientific · Model Jouan IG 650
Ideal for cultures on semi-solid media or very low volumes (type microplates): Total control of evaporation of the culture media. Stable, homogeneous temperature: Recovery under five minutes after 30 sec opening with patented heat generator. 40 liter water jacket plus insulation. Constant Relative Humidity: Fast RH recovery thanks to built-in patented vapor generator Adjustable Relative Humidity: Range 65% to 98% to provide a natural environment. Not just a display. Protected gas supply: Twin CO2 inputs with built-in shuttle valve maintains the supply when one cylinder empties. Precise culture conditions: %RH accuracy +1%. Temp. accuracy +0.1°C, homogeneity +0.25°C. CO2 accuracy +0.1%, homogeneity +0.25%. Protection against contamination: HEPA-type 0.22µm sterile membrane filtration of gas and water. High precision: Infra-Red CO2 detector, independent of temperature and humidity. Microprocessor controlled. Thermal buffer: Water jacket and insulated walls protect against temperature variation. Fully alarmed: All control parameters plus water level and door ajar. Traceability guaranteed : Optional RS 232C interface enables monitoring and remote control of the incubator. Space saving independence: Units are stackable while retaining individual controls.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Chamber out of set-point range, alarm.
Root cause: Heater element or sensor drift.
Symptoms: Gas concentration alarm, contamination risk.
Root cause: Gas sensor or solenoid valve wear.
Symptoms: Humidity drift, condensation.
Root cause: Aged door gasket.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| CO2 sensor | Periodic replacement | $$$ | Moderate |
| Door gasket / seal | Periodic replacement | $ | Fairly easy |
| Temperature sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.