Techne · Model DB100/3
Small, light, compact footprint - flat top surface allows units to be stacked in storage. Can hold any combination of aluminium insert blocks, depending on the model chosen. Digital models enable highly accurate temperature precision. Temperature range from ambient + 5°C to 200°C depending on the model chosen. Fast heat-up rate: 25°C to 100°C in 7-9 minutes, depending on the model chosen. Advanced temperature control. Temperature stability at 37°C ± 0.1°C. Outer casing is cool to the touch, even at maximum operating temperature. Temperature range from ambient to 100°C or 200°C, depending on the model chosen. Accurate, reproducible, rapid and safe heating of your samples. High quality, precision-engineered blocks provide excellent thermal contact. Choice of models with 2, 3 or 4 interchangeable blocks. Versatile range of interchangeable heating blocks to fit all popular sample tubes and plates. Full range of models and options for basic and advanced applications.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Chamber out of set-point range, alarm.
Root cause: Heater element or sensor drift.
Symptoms: Gas concentration alarm, contamination risk.
Root cause: Gas sensor or solenoid valve wear.
Symptoms: Humidity drift, condensation.
Root cause: Aged door gasket.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket / seal | Periodic replacement | $ | Fairly easy |
| Temperature sensor | Periodic replacement | $$ | Moderate |
| CO2 sensor | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.