
Spectrum Dynamics · Model VERITON Series
CZT columns that swivel to acquire data during acquisition Unique gantry designs to optimize 3D imaging with the digital detectors as close to the organ of interest as possible, key for sensitivity and resolution gains. A comprehensive reconstruction algorithm selection to generate the best image quality possible, with options that until know, were only used in PET/CT imaging for SUV calculation. Integrated acquisition, quantitative reconstruction and review console that allows for workflow efficient while enhancing the collaboration between the technologist and clinician.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Failed daily uniformity or a visible non-uniformity, energy-peak drift, COR out of tolerance.
Root cause: PMT gain drift, a bad PMT, crystal hydration, or electronics drift - needs tuning / calibration.
Symptoms: A cold or hot region in the flood, a specific PMT flagged, count-rate errors.
Root cause: Failed photomultiplier tube or its preamp, or a light-guide / crystal problem.
Symptoms: Detectors will not rotate, radially track, or reach position; collision-sensor trips.
Root cause: Drive motor, encoder, belt, or the body-contour / collision sensors.
Symptoms: Table will not index, height or horizontal drive faults.
Root cause: Table drive or encoder fault.
Symptoms: Acquisition hangs, studies will not reconstruct or archive.
Root cause: Acquisition or processing computer, or the network.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Photomultiplier tube / preamp | Major service part | $$$ | Difficult |
| Detector-motion drive / encoder / belt | Major service part | $$$ | Difficult |
| Table drive / encoder | Major service part | $$$ | Difficult |
| Acquisition / processing computer | Major service part | $$$ | Moderate |
| Collimator (handling cart / seals) | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
The firm received a report related to the detector housing on the D-SPECT Cardiac Scanner. Specifically, it was reported that if the detector housing securing mechanism is compromised, the detector housing may pull away from its secured position on the gantry and potentially come into contact with a patient. The reported event was discovered during set up and thus did not involve a patient or p
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio