MiE · Model Picola Scintron
Width 80 cm (31.5”) / Depth 72 cm (28”) 10Ý (25.4 cm) field of view with 37 matched 2Ý PMTs (Photomultiplier Tubes) Automated calibration for best uniformity and linearity Pre-aged PMTs ensure stable and dependable operation over many years with continous monitoring and adjusting gains for consistent and artifact free images High-integrated Detector Electronic Type FRED (Fast Response Enhanced Detector) with modern industry components for operation without interference 3/8Ý NaI(Tl) Scintillation-Crystal (optional 1/4Ý) Motorized positioning of the detector (tilt and height) via handcontroller with integrated acquisition start and anatomical marker function Selection of collimators are available to provide a variety of diagnostic applications; lead shielding for isotopes with energies up to 400 keV User friendly, intuitive software applications for all needs and requirements including connectivity via DICOM.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Failed daily uniformity or a visible non-uniformity, energy-peak drift, COR out of tolerance.
Root cause: PMT gain drift, a bad PMT, crystal hydration, or electronics drift - needs tuning / calibration.
Symptoms: A cold or hot region in the flood, a specific PMT flagged, count-rate errors.
Root cause: Failed photomultiplier tube or its preamp, or a light-guide / crystal problem.
Symptoms: Detectors will not rotate, radially track, or reach position; collision-sensor trips.
Root cause: Drive motor, encoder, belt, or the body-contour / collision sensors.
Symptoms: Table will not index, height or horizontal drive faults.
Root cause: Table drive or encoder fault.
Symptoms: Acquisition hangs, studies will not reconstruct or archive.
Root cause: Acquisition or processing computer, or the network.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Photomultiplier tube / preamp | Major service part | $$$ | Difficult |
| Detector-motion drive / encoder / belt | Major service part | $$$ | Difficult |
| Table drive / encoder | Major service part | $$$ | Difficult |
| Acquisition / processing computer | Major service part | $$$ | Moderate |
| Collimator (handling cart / seals) | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.