IS2 · Model Pulse CDC
Maximum functionality and easy set-up Improved SPECT image quality with accurate Center of Rotation (COR) Low cost solutions for patient overflow situations Intrinsic spatial resolution 3.1mm F.W.H.M. Uniformity +/-2.0% integral +/-1.5% differential Energy resolution 9.3% Large FOV: 14 x 9.4 inches, no clipping of hearts 450lbs bed capacity No knocking down walls (fits through 32in door) No reinforcing floors (camera weight 1850lbs.) No leveling floors (self leveling) No extra power needed (120v outlet, 15A receptacle) Equipped for Europe and international power standards 180° and 360° imaging both possible - your choice Supine or prone imaging both possible Available in a lower cost single head version (easily upgrades to dual head in the field)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.