Sirona · Model Siroclave B
Safety. Optimum steam penetration thanks to fractionated pre-vacuum. Bowie & Dick test program. Automatic sterilization cycle. Helix test program. Vacuum test program. Microprocessors prevent operator errors. Documentation function (optional). Bacteria filter Ergonomics. Easy to operate. Minimum care and maintenance requirements thanks to DUAL Water system. Automatic maintenance cycle Precision. Pre-vacuum with up to 4 vacuum phases. Post-sterilization vacuum phase for complete drying. Ideal for difficult sterilization jobs (hollow instruments, Class A+B)– for example, surgical cassettes, textiles, as well as high-speed, straight and contra-angle handpieces. Complies with the most stringent hygiene standards (prEN 13060-1/-2, Class B) Performance. 4 programs cater for all your instrument sterilization requirements. High throughput thanks to large-capacity sterilization chamber. Twin membrane vacuum pump for the rapid evacuation of the sterilization chamber. Excellent thermal insulation minimizes power consumption. Differentiated heating system ensures even, material-friendly temperature distribution. Nickel-coated sterilization chamber – substantially harder than stainless steel.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Cycle aborts, temperature or pressure not reached / held, failed BI or chemical indicator.
Root cause: Heater / element fault, a door-gasket leak, a steam-generation or water-fill fault, a blocked chamber drain / strainer, or a temperature / pressure-sensor fault.
Symptoms: Steam leak at the door, door will not seal, lock or unlock, pressure will not build.
Root cause: Worn door gasket or a door-lock / interlock fault.
Symptoms: Instruments / packs come out wet.
Root cause: Drying-phase vacuum / heater fault, an overloaded chamber, or a clogged drain.
Symptoms: Low-water alarm, mineral scale, cloudy chamber, poor steam quality.
Root cause: Empty or scaled reservoir, a fill-valve / pump fault, or use of non-distilled water.
Symptoms: Failed Bowie-Dick / air-removal test, slow come-up, air pockets.
Root cause: Blocked steam trap, a vacuum-pump / ejector fault, or a check-valve fault.
Symptoms: No or faint cycle printout.
Root cause: Thermal print head or paper.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket | Periodic replacement | $$ | Fairly easy |
| Heating element / steam-generator element | Major service part | $$$ | Difficult |
| Chamber / feedwater strainer & fill valve | Periodic replacement | $$ | Moderate |
| Temperature / pressure sensor | Major service part | $$ | Moderate |
| Steam trap / solenoid & check valves | Periodic replacement | $$ | Moderate |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.