Sentinelle Medical Inc. · Model Vanguard Breast MR Auxiliary Table
With features not available in traditional breast MRI coils, this next-generation system optimizes imaging and access, patient care and comfort, and practice efficiency. Variable Coil Geometry allows imaging coils to be customized for each breast of every patient, improving signal-to-noise ratio over fixed coils. Patient support features state-of-the-art ergonomics to comfortably accommodate patients with arms at side and arms over the head positioning. The support arches of the system not only provide support for this positioning but also protect the patient from the magnet. The Sentinelle Vanguard for GE offers a detachable table with comprehensive features – storage drawers, tray tables, biopsy grids, padding, safety rails, movable sternum supports and integrated lighting – that work together to improve workflow. Maximize your efficiencies, use two Sentinelle for GE tables; this will result in significant time savings – as much as 18 minutes in per-patient magnet use time for imaging and up to 33 minutes for interventional procedures.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead lines, failed flat-field calibration, failed ACR / MQSA phantom.
Root cause: Detector degradation, a calibration issue, or a bad pixel map.
Symptoms: Compression will not apply or hold the set force, paddle not recognised, force readout wrong.
Root cause: Compression drive / motor, the force sensor, or a paddle-detect fault.
Symptoms: C-arm will not rotate / lock, angle readout wrong, or the acquisition workstation loses the gantry.
Root cause: Rotation drive / brake / encoder, or the gantry-to-AWS link.
Symptoms: Exposure inhibited, kV / mAs error, tube-overload interlock, AEC fault.
Root cause: Generator, the mammo tube / filters, or the AEC.
Symptoms: Images will not display, mark-up or send to PACS / review workstation.
Root cause: AWS PC or the DICOM configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| Compression drive / force sensor | Major service part | $$$ | Difficult |
| C-arm rotation drive / encoder | Major service part | $$$ | Difficult |
| Mammo X-ray tube / filter assembly | Major service part | $$$$ | Expert-level |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.