Hologic · Model Lorad M-IV Series
Exceptional Patient Comfort, Convenience, and Precision - The soft lines and trim silhouette of the M-IV Series enhances patient comfort and ease of positioning, while the recessed face shield and narrow tube head permit flexible and relaxed positioning of the patient Improved Patient Management and Throughput - Patient Scheduling feature allows the technologist to enter up to 100 patients 3-Cell, 7 Position Automatic Exposure Control(AEC) Sensor - This automatic sensor can be positioned in any of seven locations, extending up to 12.5 cm from the chest wall to allow greater and more precise tissue sampling and accurate calculation of proper exposure technique. Even large breasts pose no problem with the increased range of extension Automatic Collimation - Eliminates manual apertures. The field of view is adjusted according to the attached compression device, ensuring that the correct collimation has been selected HTC grid - High Transmission Cellular Grid provides higher contrast images Bi-angular X-ray Tube - Custom designed high performance tube for enhanced magnification views FAST Paddle - Exclusive fully automated self-adjusting tilt paddle, for more uniform compression
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.