Hologic · Model Lorad M-IV Series
Exceptional Patient Comfort, Convenience, and Precision - The soft lines and trim silhouette of the M-IV Series enhances patient comfort and ease of positioning, while the recessed face shield and narrow tube head permit flexible and relaxed positioning of the patient Improved Patient Management and Throughput - Patient Scheduling feature allows the technologist to enter up to 100 patients 3-Cell, 7 Position Automatic Exposure Control(AEC) Sensor - This automatic sensor can be positioned in any of seven locations, extending up to 12.5 cm from the chest wall to allow greater and more precise tissue sampling and accurate calculation of proper exposure technique. Even large breasts pose no problem with the increased range of extension Automatic Collimation - Eliminates manual apertures. The field of view is adjusted according to the attached compression device, ensuring that the correct collimation has been selected HTC grid - High Transmission Cellular Grid provides higher contrast images Bi-angular X-ray Tube - Custom designed high performance tube for enhanced magnification views FAST Paddle - Exclusive fully automated self-adjusting tilt paddle, for more uniform compression.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead lines, failed flat-field calibration, failed ACR / MQSA phantom.
Root cause: Detector degradation, a calibration issue, or a bad pixel map.
Symptoms: Compression will not apply or hold the set force, paddle not recognised, force readout wrong.
Root cause: Compression drive / motor, the force sensor, or a paddle-detect fault.
Symptoms: C-arm will not rotate / lock, angle readout wrong, or the acquisition workstation loses the gantry.
Root cause: Rotation drive / brake / encoder, or the gantry-to-AWS link.
Symptoms: Exposure inhibited, kV / mAs error, tube-overload interlock, AEC fault.
Root cause: Generator, the mammo tube / filters, or the AEC.
Symptoms: Images will not display, mark-up or send to PACS / review workstation.
Root cause: AWS PC or the DICOM configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| Compression drive / force sensor | Major service part | $$$ | Difficult |
| C-arm rotation drive / encoder | Major service part | $$$ | Difficult |
| Mammo X-ray tube / filter assembly | Major service part | $$$$ | Expert-level |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.