Hologic · Model Selenia Dimensions
• Exceptionally sharp images • Seamless transition between imaging modes • Sophisticated user tools that simplify operation • Advanced clinical applications • Tomosynthesis-guided biopsy • Ergonomic design for patient comfort and ease of operation • A 41% increase in invasive breast cancer detection High-resolution display: • Images that can be instantly viewed on a 2 MP or 3MP DICOM-calibrated display, providing exceptionally fine detail. • Allows prior breast imaging studies to be recalled, making it possible to view new and prior images side-by-side. Optimized face shield: • Retractable to help when positioning patients. • Stationary during 3D™ imaging, allowing patients to be positioned as they are for 2D imaging. FAST Paddle system: • Conforms to natural contours of the breast, providing greater comfort to the patient and more even compression across the entire breast. • All paddles used for 2D and 3D™ imaging.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.