SciCan · Model BRAVO
• Speed - The BRAVO line of chamber autoclaves is one of the fastest on the market today. BRAVO offers a perfect blend of speed and chamber capacity coupled with our drying technology to ensure your daily output of reprocessed instruments can not be rivaled. • Dryness - With closed door drying and the Dri-Tec drying system, the BRAVO gives you lightning fast & consistent dry loads every time to allow more loads to be processed daily. • Versatility - The BRAVO offers numeroussterilization cycles with a wide array of parameters. This allows the user to choose the appropriate cycle for the load, be it wrapped or unwrapped. • Ease of use - The BRAVO can be initiated by a single button. Once the BRAVO has been properly loaded, the user can choose from one of four pre-set cycles as defined by the user.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.