QRS Diagnostic · Model SpiroCard
Standards: The QRS SpiroCard spirometer provides effective diagnostic tests and meets the following Standards: American Thoracic Society (ATS/ERS) 2005 Standard British Thoracic Society (BTS) Standard National Institute for Health & Clinical Excellence (NICE) Guidelines Lung Age Calculation: Lung age is calculated for patients ages 20-84. It is equal to the predicted FEV1 that matches the patients actual FEV1. Lung age may differ based on the predicted equation chosen. Patented, Pre-Calibrated Mouthpiece: With the QRS SpiroCard spirometry system, everything the patient touches is thrown away. No sterilization or calibration is necessary, saving time for nurses, therapist and physicians. No Batteries Required: The QRS SpiroCard spirometer draws its power from the PC it is connected to via USB port.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The respiratory therapy is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Synced live from the FDA openFDA API.
QRS Diagnostic has initiated a recall involving Universal ECG 12 Lead IEC ECG Devices. This recall has been initiated because the chest lead wires on these devices may have been improperly labeled. Incorrect labeling of the lead wires could result in improper lead wire placement on the patient which may result in inaccurate waveforms being displayed to the user and an inaccurate interpretatio